Home > Products >Trauma and Extremities >Distal Lateral Humeral LCP (L&R)
Distal Lateral Humeral LCP (L&R)
Overview

Part Number: 1307-0932 ~ 1307-2032 (Left F1295) 6307-0932 ~ 6307-2032 (Left F138)
Part Number: 1308-0932 ~ 1308-2032 (Right F1295) 6308-0932 ~ 6308-2032 (Right F138)

Humeral Locking Compression Plate Series

Distal Lateral Humeral LCP (L&R)

The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required.

TC20: New Material Without Vanadium Trouble

Features
The SurgTech Trauma System is available in a wide range of sizes: 94-204mm L / 4,6,8,10,11 hole / 2.5mm t / 11mm w.
The features that deserve special attention are:
Features
  • Matching Screws
  • Stable Angle Formation
  • Limited Contact Profile Design
  • Anatomic Pre-plastic Design
    Stable angle formation, more suitable for osteoporosis or complex fractures.
    The limited contact profile design greatly reduces the damage to the periosteum blood supply.
    Anatomic pre-plastic design, the best and comfortable clothing bone surface.

Materials: TC20     Full Name: Ti6Al7Nb
It is a new type of implant material with high technology content and high economic value. Standards implemented in different countries and regions include: ISO5832-11, ASTM F1295, GB/T13810, GB 23102.

Chemical Composition


TC20 VS TC4


Differences between TC20 and TC4
TC20 (Ti6Al7Nb) and TC4(Ti-6Al-4V) belong to alpha + beta-titanium alloy. The main difference is that TC20 uses the non-toxic element niobium (Nb) instead of the toxic element vanadium (V) in TC4.

Advantage of Difference
1. The potential cytotoxicity of element V is eliminated and the material has good cytocompatibility.
2. Nb element can promote the density increase of passivation film formed by surface oxidation of ti-6al-7nb alloy, so that the material has good corrosion resistance.
3. The oxides and hydroxides of titanium, aluminum and niobium have reached saturation, and the dissolved metals in the implants will not be ionized or transferred in the body, making them have good biocompatibility.
Instruments
Instruments
  • A Full Set of Tools Layer I
  • A Full Set of Tools Layer II
    1. Drill φ2.8x165; 2. Probe φ2x160; 3. Broken Nail Extractor; 4. Countersink; 5. Skid Extractor; 6. Drill φ2.5; 7. Plum Blossom Screwdriver; 8. Bender (right); 9. T-type Quick Change Handle; 10. Depth Gauge; 11. Drill Bush  φ2.8; 12. Screw Tap 3.5; 13. Screw Tap 4.0; 14. Thread Guide Sleeve; 15. Guide Handle; 16. Drill Bushing φ2.5; 17. Guide Sleeve φ3.5; 18. Guide Sleeve φ4.0; 19. Eccentric Drill Sleeve φ2.5; 20. Wrench; 21. Bender (left); 22. Drill Bushing φ2.5; 23. Drill φ3.5; 24. Nail Holder; 25. Stopper φ3.0; 26. Fast Switching Adapter.
    27. Torque Wrench; 28. Tip Reduction Forceps (Middle); 29. Bending Reset Forceps; 30. Centralized Bone Holding Forceps (Middle); 31. Ratchet Wrench.
Indication

Follow us:

Copyright © 2019 SurgTech Inc. All Rights Reserved. Designed by Wanhu