Home > Products >Trauma and Extremities >Distal Radius LCP (L&R)
Distal Radius LCP (L&R)
Overview

Part Number: 1306-4820 ~ 1306-9320 (Left F1295) 6306-4820 ~ 6306-9320 (Left F138)
Part Number: 1307-4820 ~ 1307-9320 (Right F1295) 6307-4820 ~ 6307-9320 (Right F138)

Distal Radius LCP (L&R)

The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required.

TC20: New Material Without Vanadium Trouble

 

Features
The SurgTech Trauma System is available in a wide range of sizes: 48-93mm L / 3,4,5,6,8 hole / 2.0mm t / 9mm w.
The features that deserve special attention are:
Features
  • Matching Screws
  • Low Notch Design of Plate Body
  • Distal Screw Facing Articular Surface
  • Design of Multi-row Screw Holes & Angles
  • Anatomical Design
    Low notch design, high polishing surface, effectively avoid tendon irritation and adhesion.
    Rows of distal screws toward the articular surface provide angular stability and disperse fixation of the radial styloid process and the dorsal displaced bone mass.
    The multi-row screw holes and angular design provide perfect support for the entire articular surface and better grip the fracture block.
    In anatomic design, the obtuse edge of the head of the bone plate is located on the side of the radial styloid process.

Materials: TC20     Full Name: Ti6Al7Nb
It is a new type of implant material with high technology content and high economic value. Standards implemented in different countries and regions include: ISO5832-11, ASTM F1295, GB/T13810, GB 23102.

Chemical Composition


TC20 VS TC4


Differences between TC20 and TC4

TC20 (Ti6Al7Nb) and TC4(Ti-6Al-4V) belong to alpha + beta-titanium alloy. The main difference is that TC20 uses the non-toxic element niobium (Nb) instead of the toxic element vanadium (V) in TC4.


Advantage of Difference
1. The potential cytotoxicity of element V is eliminated and the material has good cytocompatibility.
2. Nb element can promote the density increase of passivation film formed by surface oxidation of ti-6al-7nb alloy, so that the material has good corrosion resistance.
3. The oxides and hydroxides of titanium, aluminum and niobium have reached saturation, and the dissolved metals in the implants will not be ionized or transferred in the body, making them have good biocompatibility.
Instruments
Instruments
  • A Full Set of Tools Layer I
  • A Full Set of Tools Layer II
    1. Guide Pin Drill Sleeve φ1.5; 2. Guide Pin φ1.5x150; 3. Drill φ2.0x120; 4. Lock Drill Sleeve With Scale 2.0; 5. Screw Tap; 6. Guider; 7. Depth Gauge; 8. Drill φ2.7x120; 9. Drill φ1.8; 10. Lock Drill Sleeve With Scale 1.8; 11. Screwdriver; 12: T-type Quick Change Handle; 13: Periosteal Dissector (Round); 14: Periosteal Stripper (Flat); 15: Universal Angle Guide; 16: Quick Connection Handle;
    1. Torque Wrench; 2. Tip Reduction Forceps (Middle); 3. Bending Reset Forceps; 4. Flat Nose Pliers With Pointed Tips; 5. Tip Reposition Forceps.
Indication


1. Distal Radius Osteotomy;


2. Distal Radial Extra-articular Fracture;

3. Intra-articular Fracture of the Distal Radius;

4. Comminuted Fracture of Distal Radius.

Follow us: