Home > Products >Trauma and Extremities >Distal Lateral Fibula LCP (L&R)
Distal Lateral Fibula LCP (L&R)
Overview

Part Number: 1506-0725 ~ 1506-1425 (Left F1295) 6506-0725 ~ 6506-1425 (Left F138)
Part Number: 1507-0725 ~ 1507-1425 (Right F1295) 6507-0725 ~ 6507-1425 (Right F138)

Fibula Locking Compression Plate Series

Distal Lateral Fibula LCP (L&R)

The SurgTech Trauma System is a plate and screw fixation system. Plates and screws are offered in “mini”,“small” and “large” set sizes in a variety of shapes based upon the anatomical fixation required.

TC20: New Material Without Vanadium Trouble

 

Features
The SurgTech Trauma System is available in a wide range of sizes: 74-139mm L / 3,4,5,6,8 hole / 2.5mm t / 9.5mm w.
The features that deserve special attention are:
Features
  • Matching Screws
  • A Variety of Screw Options
  • Proximal Round Blunt Design
  • Anatomy Preshaping
    Five circular locking holes and four coaxial holes provide a wide selection of screws.
    The proximal round blunt design facilitates minimally invasive implantation.


Materials: TC20     Full Name: Ti6Al7Nb


It is a new type of implant material with high technology content and high economic value. Standards implemented in different countries and regions include: ISO5832-11, ASTM F1295, GB/T13810, GB 23102.

 

Chemical Composition


TC20 VS TC4


Differences between TC20 and TC4

TC20 (Ti6Al7Nb) and TC4(Ti-6Al-4V) belong to alpha + beta-titanium alloy. The main difference is that TC20 uses the non-toxic element niobium (Nb) instead of the toxic element vanadium (V) in TC4.


Advantage of Difference

1. The potential cytotoxicity of element V is eliminated and the material has good cytocompatibility.

2. Nb element can promote the density increase of passivation film formed by surface oxidation of ti-6al-7nb alloy, so that the material has good corrosion resistance.

3. The oxides and hydroxides of titanium, aluminum and niobium have reached saturation, and the dissolved metals in the implants will not be ionized or transferred in the body, making them have good biocompatibility.

Instruments
Instruments
  • A Full Set of Tools Layer I
  • A Full Set of Tools Layer II
    1. Drill φ4.3; 2. Guide Pin φ2x280; 3. Broken Nail Extractor; 4. Countersink; 5. Skid Extractor φ3.5; 6. Screwdriver T25; 7. Depth Gauge; 8. Locking Bushing φ4.3; 9. Drill φ3.2; 10. Drill φ4.5; 11. Screw Tap HA4.5; 12. Screw Tap HB6.5; 13. Thread Guide Sleeve; 14. Drill Bushing φ3.2; 15. Guide Sleeve φ4.5; 16. Guide Sleeve φ6.5; 17. Eccentric Drill Sleeve φ3.2; 18. Guide Handle; 19. Drill Bushing φ3.2; 20. Wrench 21. T-type Quick Change Handle; 22. Nail Holder; 23. Stopper; 24. Fast Switching Adapter.
    1. Plate Bender (RIGHT); 2. Plate Bender (LEFT); 3. Torque Wrench; 4. Reset Pliers (Large); 5. Centralized Forceps Holder (Large); 6. Tip Reduction Forceps (Large); 7. Ratchet Wrench
Indication

Follow us:

Copyright © 2019 SurgTech Inc. All Rights Reserved. Designed by Wanhu